{"id":47034,"date":"2026-06-17T15:42:15","date_gmt":"2026-06-17T13:42:15","guid":{"rendered":"https:\/\/www.cloudmagazin.com\/?p=47034"},"modified":"2026-07-06T02:47:49","modified_gmt":"2026-07-06T00:47:49","slug":"800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud","status":"publish","type":"post","link":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/","title":{"rendered":"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud"},"content":{"rendered":"<p style=\"color:#6190a9;font-size:0.9em;margin:0 0 16px;padding:0;\">6 Min. temps de lecture<\/p>\n<p><strong>Un seul rack d\u00e9di\u00e9 \u00e0 l&rsquo;IA d\u00e9veloppe une puissance qui d\u00e9passe de plusieurs fois celle d&rsquo;un rack serveur classique.<\/strong> NVIDIA pr\u00e9voit pour la prochaine g\u00e9n\u00e9ration des racks allant de 100 kilowatts \u00e0 plus d&rsquo;un m\u00e9gawatt. Cela pousse la distribution \u00e9lectrique classique des data centers vers une limite physique : avec les 54 volts en courant continu actuellement utilis\u00e9s dans les racks, il faudrait installer des barres de cuivre si \u00e9paisses que le poids, les pertes et l&rsquo;encombrement freineraient le d\u00e9ploiement. La r\u00e9ponse de NVIDIA s&rsquo;appelle le 800 volts en courant continu haute tension, introduit avec la g\u00e9n\u00e9ration Rubin. Pour quiconque planifie des capacit\u00e9s cloud ou exploite des data centers, cela d\u00e9termine le choix du site et le budget.<\/p>\n<h2>Les points cl\u00e9s en bref<\/h2>\n<ul>\n<li><strong>La densit\u00e9 \u00e9nerg\u00e9tique d\u00e9passe l&rsquo;ancien concept de distribution :<\/strong> les racks IA tendent vers le m\u00e9gawatt, et la distribution actuelle en 54 volts dans le rack ne suit plus physiquement. Le 800 volts en courant continu repousse cette limite.<\/li>\n<li><strong>Moins de cuivre, plus de puissance, moins de pertes :<\/strong> NVIDIA chiffre l&rsquo;avantage \u00e0 environ 45 % de cuivre en moins, 85 % de puissance transmise en plus sur le m\u00eame conducteur et jusqu&rsquo;\u00e0 30 % de co\u00fbts totaux r\u00e9duits sur la dur\u00e9e de vie.<\/li>\n<li><strong>La transition se fait par \u00e9tapes :<\/strong> premiers racks \u00e0 haute densit\u00e9 d\u00e8s le second semestre, l&rsquo;architecture compl\u00e8te en 800 volts avec les syst\u00e8mes Kyber denses \u00e0 partir de 2027. Ceux qui planifient des espaces aujourd&rsquo;hui se pr\u00e9parent d\u00e9j\u00e0 pour ce monde.<\/li>\n<\/ul>\n<p style=\"font-size:0.88em;color:#666;margin:20px 0 32px 0;border-top:1px solid #e5e5e5;border-bottom:1px solid #e5e5e5;padding:10px 0;\"><span style=\"color:#004a59;font-weight:700;text-transform:uppercase;font-size:0.72em;letter-spacing:0.14em;margin-right:14px;\">En lien :<\/span><a href=\"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/13\/inference-desagregee-pourquoi-aws-et-cerebras-separent-gpu\/\" style=\"color:#333;text-decoration:underline;\">Inference d\u00e9sagr\u00e9g\u00e9e : pourquoi AWS et Cerebras s\u00e9parent le GPU<\/a>&nbsp;&nbsp;<span style=\"color:#ccc;\">\/<\/span>&nbsp;&nbsp;<a href=\"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/14\/broker-de-cloud-plutot-que-chaos-de-cloud-30-de-reduction-des-couts-de-multi\/\" style=\"color:#333;text-decoration:underline;\">Courtier cloud plut\u00f4t que chaos cloud : 30 % de co\u00fbts en moins en multi-cloud<\/a><\/p>\n<h2 style=\"margin-top:64px;margin-bottom:20px;padding-top:16px;\">Pourquoi la distribution en 54 volts atteint ses limites<\/h2>\n<p>La physique est simple : la puissance est \u00e9gale \u00e0 la tension multipli\u00e9e par l&rsquo;intensit\u00e9. Si l&rsquo;on maintient une tension basse tout en augmentant la puissance dans un rack, il faut augmenter l&rsquo;intensit\u00e9. Plus d&rsquo;intensit\u00e9 signifie des conducteurs plus \u00e9pais, plus de chaleur et des pertes accrues \u00e0 chaque m\u00e8tre de cuivre. Pour un rack de quelques kilowatts, cela ne p\u00e8se pas lourd. Mais pour un rack approchant le m\u00e9gawatt, la barre de distribution devient un composant avec son propre poids, son propre syst\u00e8me de refroidissement et ses propres risques de maintenance.<\/p>\n<p>Aujourd&rsquo;hui, la distribution dans le rack s&rsquo;effectue g\u00e9n\u00e9ralement en 54 volts en courant continu, aliment\u00e9e par l&rsquo;alimentation triphas\u00e9e du b\u00e2timent en 415 ou 480 volts. Chaque \u00e9tage de conversion sur ce chemin r\u00e9duit le rendement, et chaque barre de distribution devant alimenter un rack d&rsquo;un m\u00e9gawatt devient d&rsquo;un poids ing\u00e9rable. C&rsquo;est pr\u00e9cis\u00e9ment ici que le passage \u00e0 800 volts intervient : une tension plus \u00e9lev\u00e9e signifie, \u00e0 puissance \u00e9gale, une intensit\u00e9 moindre, donc des conducteurs plus fins et des pertes r\u00e9duites. C&rsquo;est de la physique \u00e9l\u00e9mentaire.<\/p>\n<p>Dans l&rsquo;exploitation des data centers, cela se r\u00e9percute \u00e0 plusieurs niveaux. Les barres de cuivre \u00e9paisses n\u00e9cessitent de l&rsquo;espace, des fixations et un refroidissement d\u00e9di\u00e9, elles compliquent la maintenance et les modifications, et le cuivre, en tant que mati\u00e8re premi\u00e8re, est co\u00fbteux et difficile \u00e0 planifier. Chaque \u00e9tage de conversion entre le raccordement au r\u00e9seau et la puce g\u00e9n\u00e8re de la chaleur suppl\u00e9mentaire, qui doit elle-m\u00eame \u00eatre \u00e9vacu\u00e9e. Augmenter la densit\u00e9 \u00e9nerg\u00e9tique sans relever la tension ne fait que d\u00e9placer le probl\u00e8me de la puissance de calcul vers la technique du b\u00e2timent, o\u00f9 sa r\u00e9solution est bien plus co\u00fbteuse.<\/p>\n<h2 style=\"margin-top:64px;margin-bottom:20px;padding-top:16px;\">Ce que change concr\u00e8tement le 800 volts continu<\/h2>\n<p>NVIDIA a pr\u00e9sent\u00e9 l&rsquo;architecture 800 volts comme solution d&rsquo;alimentation pour les futures usines d&rsquo;IA. L&rsquo;\u00e9lectricit\u00e9 arrive en 13,8 kilovolts alternatifs et est convertie directement en 800 volts continus, sans la cascade actuelle de plusieurs \u00e9tages de conversion dans le rack. Cela permet d&rsquo;\u00e9conomiser des composants susceptibles de tomber en panne et r\u00e9duit les points o\u00f9 le rendement est perdu. Les chiffres avanc\u00e9s par le fabricant montrent pourquoi il ne s&rsquo;agit pas d&rsquo;un simple d\u00e9tail technique.<\/p>\n<div style=\"display:flex;flex-wrap:wrap;gap:16px;border-top:3px solid #0bb7fd;padding-top:18px;margin:28px 0;\">\n<div style=\"flex:1;min-width:150px;\">\n<div style=\"font-size:2em;font-weight:800;color:#0bb7fd;line-height:1;\">45 %<\/div>\n<div style=\"font-size:0.9em;color:#555;margin-top:6px;\"><strong>moins de cuivre<\/strong> pour le raccordement des racks par rapport aux syst\u00e8mes actuels, selon NVIDIA.<\/div>\n<\/div>\n<div style=\"flex:1;min-width:150px;\">\n<div style=\"font-size:2em;font-weight:800;color:#0bb7fd;line-height:1;\">85 %<\/div>\n<div style=\"font-size:0.9em;color:#555;margin-top:6px;\"><strong>plus de puissance<\/strong> pour la m\u00eame section de conducteur, car la tension augmente au lieu de l&rsquo;intensit\u00e9.<\/div>\n<\/div>\n<div style=\"flex:1;min-width:150px;\">\n<div style=\"font-size:2em;font-weight:800;color:#0bb7fd;line-height:1;\">jusqu&rsquo;\u00e0 30 %<\/div>\n<div style=\"font-size:0.9em;color:#555;margin-top:6px;\"><strong>r\u00e9duction des co\u00fbts globaux<\/strong> sur la dur\u00e9e de vie, avec jusqu&rsquo;\u00e0 cinq pour cent de meilleur rendement et jusqu&rsquo;\u00e0 70 pour cent de maintenance en moins.<\/div>\n<\/div>\n<\/div>\n<p>Pour les exploitants, l&rsquo;aspect maintenance est souvent plus crucial que le rendement. Moins d&rsquo;\u00e9tages de conversion signifie moins d&rsquo;alimentations susceptibles de tomber en panne et moins d&rsquo;interventions techniques. NVIDIA \u00e9voque une r\u00e9duction pouvant atteindre 70 pour cent des op\u00e9rations de maintenance. Quiconque a d\u00e9j\u00e0 remplac\u00e9 en pleine nuit une alimentation grill\u00e9e dans une rang\u00e9e compl\u00e8te sait que ce chiffre est plus r\u00e9aliste en conditions r\u00e9elles que n&rsquo;importe quel benchmark.<\/p>\n<p>Pour un seul rack, cinq pour cent de rendement suppl\u00e9mentaire semblent peu. Mais dans un hall abritant des centaines de racks fonctionnant 24 heures sur 24, la diff\u00e9rence s&rsquo;accumule jusqu&rsquo;\u00e0 atteindre un niveau visible sur la facture \u00e9nerg\u00e9tique et la charge de refroidissement. C&rsquo;est pr\u00e9cis\u00e9ment pour cette raison que l&rsquo;architecture \u00e9lectrique n&rsquo;est pas une simple question mat\u00e9rielle, mais un levier d&rsquo;ajustement des co\u00fbts d&rsquo;exploitation sur toute la dur\u00e9e de vie d&rsquo;une installation. Pour les exploitants qui con\u00e7oivent aujourd&rsquo;hui des espaces pour les dix prochaines ann\u00e9es, elle d\u00e9termine aussi combien de puissance de calcul par m\u00e8tre carr\u00e9 et par watt sera \u00e9conomiquement viable \u00e0 terme.<\/p>\n<h2 style=\"margin-top:64px;margin-bottom:20px;padding-top:16px;\">La feuille de route jusqu&rsquo;en 2027<\/h2>\n<p>La transition ne se fera pas du jour au lendemain. NVIDIA la d\u00e9ploie avec la g\u00e9n\u00e9ration Rubin, et les fournisseurs de composants \u00e9lectroniques de puissance et d&rsquo;\u00e9quipements pour data centers suivent le mouvement. Point important pour la planification : l&rsquo;\u00e9tape interm\u00e9diaire est d\u00e9j\u00e0 l\u00e0, et la phase finale est pr\u00e9visible.<\/p>\n<div style=\"margin:28px 0;\">\n<div style=\"display:flex;gap:16px;padding:12px 0;border-bottom:1px solid #e5e5e5;\">\n<div style=\"min-width:130px;font-weight:700;color:#004a59;\">\u00c0 partir du S2 2026<\/div>\n<div style=\"color:#333;line-height:1.6;\">Les racks VR200 de la plateforme Vera-Rubin affichent, selon NVIDIA, une puissance d&rsquo;environ 190 \u00e0 230 kilowatts. Les premiers produits 800 volts de fournisseurs comme Vertiv sont attendus pour le second semestre.<\/div>\n<\/div>\n<div style=\"display:flex;gap:16px;padding:12px 0;border-bottom:1px solid #e5e5e5;\">\n<div style=\"min-width:130px;font-weight:700;color:#004a59;\">2027<\/div>\n<div style=\"color:#333;line-height:1.6;\">Les syst\u00e8mes Kyber denses int\u00e8grent l&rsquo;architecture 800 volts compl\u00e8te, con\u00e7ue pour environ 600 kilowatts par rack avec jusqu&rsquo;\u00e0 576 acc\u00e9l\u00e9rateurs Rubin Ultra et un refroidissement liquide int\u00e9gr\u00e9.<\/div>\n<\/div>\n<div style=\"display:flex;gap:16px;padding:12px 0;\">\n<div style=\"min-width:130px;font-weight:700;color:#004a59;\">L&rsquo;\u00e9cosyst\u00e8me<\/div>\n<div style=\"color:#333;line-height:1.6;\">NVIDIA cite des partenaires dans les domaines des semi-conducteurs et des infrastructures de data centers, dont Analog Devices, Infineon, Delta, Eaton, Schneider Electric et Vertiv. Les standards ne se construisent donc pas en solo.<\/div>\n<\/div>\n<\/div>\n<h2 style=\"margin-top:64px;margin-bottom:20px;padding-top:16px;\">Ce que les op\u00e9rateurs cloud et d&rsquo;infrastructure doivent d\u00e9cider d\u00e8s maintenant<\/h2>\n<p>La plupart des \u00e9quipes n&rsquo;ach\u00e8tent pas des racks NVIDIA d&rsquo;une puissance de l&rsquo;ordre du m\u00e9gawatt. Pourtant, ce changement concerne tous ceux qui planifient des capacit\u00e9s, ach\u00e8tent de la colocation ou am\u00e9nagent leurs propres espaces. Quatre points doivent d\u00e9sormais \u00eatre abord\u00e9s avant que le prochain cycle d&rsquo;expansion ne se transforme en mauvaise surprise co\u00fbteuse.<\/p>\n<p><strong>Premi\u00e8rement, la densit\u00e9 de puissance par surface.<\/strong> Quiconque con\u00e7oit aujourd&rsquo;hui une salle pour des densit\u00e9s de racks classiques passe \u00e0 c\u00f4t\u00e9 de la r\u00e9alit\u00e9 de l&rsquo;IA. La question n&rsquo;est plus de savoir combien de racks tiennent sur la surface, mais quelle puissance et quel refroidissement cette surface peut supporter. Il s&rsquo;agit d&rsquo;une d\u00e9cision concernant la puissance de raccordement du site, et non le mobilier.<\/p>\n<p><strong>Deuxi\u00e8mement, le refroidissement.<\/strong> Des racks de cette densit\u00e9 ne peuvent fonctionner sans refroidissement liquide. Celui qui planifie une surface ou ach\u00e8te de la colocation v\u00e9rifie d\u00e9sormais si un refroidissement direct au niveau du processeur est pr\u00e9vu et comment la chaleur est \u00e9vacu\u00e9e. Le refroidissement par air seul n&rsquo;a plus sa place dans cette cat\u00e9gorie.<\/p>\n<p><strong>Troisi\u00e8mement, le raccordement au r\u00e9seau et le prix de l&rsquo;\u00e9lectricit\u00e9.<\/strong> Un m\u00e9gawatt par rack implique des sites o\u00f9 suffisamment de puissance est disponible et reste abordable. Cela d\u00e9place le choix des emplacements vers des r\u00e9gions b\u00e9n\u00e9ficiant d&rsquo;une alimentation stable et bon march\u00e9, et fait des contrats d&rsquo;approvisionnement \u00e9lectrique \u00e0 long terme un levier strat\u00e9gique. Pour le march\u00e9 europ\u00e9en, cela repr\u00e9sente un d\u00e9fi particulier : les raccordements au r\u00e9seau de cette envergure ne sont pas disponibles partout \u00e0 court terme, et les d\u00e9lais d&rsquo;autorisation et de d\u00e9veloppement s&rsquo;\u00e9tendent souvent sur plusieurs ann\u00e9es. Celui qui planifie une surface doit donc clarifier la puissance de raccordement disponible avec le gestionnaire de r\u00e9seau d\u00e8s le d\u00e9but, et non pas seulement lorsque le mat\u00e9riel est d\u00e9j\u00e0 command\u00e9.<\/p>\n<p><strong>Quatri\u00e8mement, la maturit\u00e9 des fournisseurs.<\/strong> Celui qui acquiert de nouvelles technologies dans les ann\u00e9es \u00e0 venir doit interroger concr\u00e8tement les fabricants d&rsquo;alimentation \u00e9lectrique et d&rsquo;armoires sur leur feuille de route en 800 volts. Une installation verrouill\u00e9e aujourd&rsquo;hui sur l&rsquo;ancien concept de distribution pourrait devenir une impasse lors du prochain bond technologique.<\/p>\n<p>Aucun de ces points n&rsquo;exige une d\u00e9cision cette semaine. Mais celui qui fige d\u00e8s maintenant les surfaces, les contrats et les achats sans cette perspective planifie pour des hypoth\u00e8ses de charge d&rsquo;hier.<\/p>\n<h2 style=\"padding-top:64px;margin-bottom:20px;\">Foire aux questions<\/h2>\n<details>\n<summary><strong>Qu\u2019est-ce que le courant continu 800 volts dans un data center ?<\/strong><\/summary>\n<p style=\"margin:8px 0 4px 24px;color:#555;line-height:1.6;\">Il s\u2019agit d\u2019une architecture d\u2019alimentation \u00e9lectrique qui achemine le courant sous haute tension continue jusqu\u2019au plus pr\u00e8s des racks, au lieu de le distribuer via plusieurs \u00e9tapes de conversion entre courant alternatif et continu comme c\u2019est le cas aujourd\u2019hui. Une tension plus \u00e9lev\u00e9e signifie, \u00e0 puissance \u00e9gale, un courant moindre, donc des conducteurs plus fins et moins de pertes. NVIDIA introduit ce concept avec la g\u00e9n\u00e9ration Rubin.<\/p>\n<\/details>\n<details>\n<summary><strong>Pourquoi la distribution actuelle en 54 volts ne suffit-elle plus ?<\/strong><\/summary>\n<p style=\"margin:8px 0 4px 24px;color:#555;line-height:1.6;\">Parce que les racks d\u00e9di\u00e9s \u00e0 l\u2019IA tendent vers le m\u00e9gawatt. \u00c0 basse tension, le courant devrait augmenter \u00e0 tel point que les barres de cuivre deviendraient ing\u00e9rables en poids et que les pertes seraient trop importantes. Le 800 volts repousse cette limite physique et rend enfin praticables des racks \u00e0 tr\u00e8s haute densit\u00e9.<\/p>\n<\/details>\n<details>\n<summary><strong>Quelles \u00e9conomies NVIDIA annonce-t-il avec cette transition ?<\/strong><\/summary>\n<p style=\"margin:8px 0 4px 24px;color:#555;line-height:1.6;\">NVIDIA \u00e9voque environ 45 % de cuivre en moins, 85 % de puissance transmise en plus via le m\u00eame conducteur, jusqu\u2019\u00e0 5 % de rendement am\u00e9lior\u00e9, jusqu\u2019\u00e0 70 % de maintenance en moins et jusqu\u2019\u00e0 30 % de co\u00fbts totaux r\u00e9duits sur la dur\u00e9e de vie. Ces chiffres proviennent du fabricant et doivent \u00eatre confront\u00e9s \u00e0 votre propre profil de charge.<\/p>\n<\/details>\n<details>\n<summary><strong>\u00c0 partir de quand cette technologie sera-t-elle disponible ?<\/strong><\/summary>\n<p style=\"margin:8px 0 4px 24px;color:#555;line-height:1.6;\">Les racks VR200, plus denses, devraient arriver au second semestre selon NVIDIA, tout comme les premiers produits 800 volts des fournisseurs. L\u2019architecture compl\u00e8te, avec les syst\u00e8mes Kyber haute densit\u00e9 et environ 600 kilowatts par rack, est pr\u00e9vue pour 2027.<\/p>\n<\/details>\n<details>\n<summary><strong>Mon \u00e9quipe doit-elle se convertir imm\u00e9diatement ?<\/strong><\/summary>\n<p style=\"margin:8px 0 4px 24px;color:#555;line-height:1.6;\">Les installations existantes continuent de fonctionner. En revanche, si vous planifiez de nouveaux espaces, achetez de la colocation ou acqu\u00e9rez du mat\u00e9riel pour les ann\u00e9es \u00e0 venir, vous devez d\u00e8s maintenant int\u00e9grer la densit\u00e9 de puissance, le refroidissement liquide, le raccordement au r\u00e9seau et la feuille de route 800 volts de vos fournisseurs. Sinon, vous risquez de vous retrouver avec une installation incapable de suivre le prochain pic de charge.<\/p>\n<\/details>\n<div style=\"margin:40px 0 24px 0;\">\n<p style=\"margin:0 0 12px 0;font-size:0.78em;font-weight:700;text-transform:uppercase;letter-spacing:0.18em;color:#666;\">Plus d&rsquo;articles du r\u00e9seau MBF Media<\/p>\n<div style=\"padding:14px 18px;border-left:3px solid #202528;background:#fafafa;margin-bottom:6px;\">\n<div style=\"font-size:0.7em;font-weight:700;color:#202528;text-transform:uppercase;letter-spacing:0.12em;margin-bottom:4px;\">mybusinessfuture<\/div>\n<p><a href=\"https:\/\/mybusinessfuture.com\/desertec-reloaded-was-wuestenstrom-fuer-die-energiekosten-bedeutet\/\" style=\"font-weight:600;line-height:1.4;color:#1a1a1a;text-decoration:none;\">Desertec Reloaded : ce que l\u2019\u00e9lectricit\u00e9 du d\u00e9sert signifie pour les co\u00fbts \u00e9nerg\u00e9tiques<\/a>\n<\/div>\n<div style=\"padding:14px 18px;border-left:3px solid #d65663;background:#fafafa;margin-bottom:6px;\">\n<div style=\"font-size:0.7em;font-weight:700;color:#d65663;text-transform:uppercase;letter-spacing:0.12em;margin-bottom:4px;\">digital-chiefs<\/div>\n<p><a href=\"https:\/\/www.digital-chiefs.de\/wann-sich-souveraener-stack-rechnet\/\" style=\"font-weight:600;line-height:1.4;color:#1a1a1a;text-decoration:none;\">Quand un stack souverain devient vraiment rentable<\/a>\n<\/div>\n<div style=\"padding:14px 18px;border-left:3px solid #69d8ed;background:#fafafa;\">\n<div style=\"font-size:0.7em;font-weight:700;color:#69d8ed;text-transform:uppercase;letter-spacing:0.12em;margin-bottom:4px;\">securitytoday<\/div>\n<p><a href=\"https:\/\/www.securitytoday.de\/2026\/06\/16\/nis2-aufsichtsphase-bsi-pflichten-deutschland\/\" style=\"font-weight:600;line-height:1.4;color:#1a1a1a;text-decoration:none;\">NIS2 apr\u00e8s l\u2019\u00e9ch\u00e9ance : la supervision du BSI commence maintenant<\/a>\n<\/div>\n<\/div>\n<p style=\"text-align:right;\"><em>Source de l&rsquo;image : g\u00e9n\u00e9r\u00e9e par IA (Juli 2026)<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"Le courant continu 800 volts brise la barri\u00e8re \u00e9lectrique dans les centres de calcul de l&rsquo;IA : moins de cuivre, plus de puissance.","protected":false},"author":31,"featured_media":48275,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_meta-robots-adv":"","_yoast_wpseo_canonical":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_opengraph-image":"","_yoast_wpseo_opengraph-image-id":0,"_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_yoast_wpseo_twitter-image":"","_yoast_wpseo_twitter-image-id":0,"pre_headline":"","bildquelle":"","teasertext":"","language":"de","_evm_translation_lang":"","featured_post":0,"featured_post_sortierung":0,"_wp_old_slug":[],"footnotes":""},"categories":[944,722],"tags":[],"industry":[],"class_list":["post-47034","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-centres-de-donnees","category-rechenzentren"],"evm_reading_time_minutes":11,"wpml_language":"fr","wpml_translation_of":46992,"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud<\/title>\n<meta name=\"description\" content=\"Le courant continu 800 volts brise le mur \u00e9lectrique dans les centres de calcul de l&#039;IA : moins de cuivre, plus de puissance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud\" \/>\n<meta property=\"og:description\" content=\"Le courant continu 800 volts brise le mur \u00e9lectrique dans les centres de calcul de l&#039;IA : moins de cuivre, plus de puissance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/\" \/>\n<meta property=\"og:site_name\" content=\"cloudmagazin\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cloudmagazincom\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-17T13:42:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-06T00:47:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/07\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1792\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alec Chizhik\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@cloudmagazin\" \/>\n<meta name=\"twitter:site\" content=\"@cloudmagazin\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alec Chizhik\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"NewsArticle\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/\"},\"author\":{\"name\":\"Alec Chizhik\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#\\\/schema\\\/person\\\/ce38baaa19a580268aedce096597eb3c\"},\"headline\":\"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud\",\"datePublished\":\"2026-06-17T13:42:15+00:00\",\"dateModified\":\"2026-07-06T00:47:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/\"},\"wordCount\":2009,\"publisher\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg\",\"articleSection\":[\"Centres de donn\u00e9es\",\"Centres de donn\u00e9es\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/\",\"url\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/\",\"name\":\"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg\",\"datePublished\":\"2026-06-17T13:42:15+00:00\",\"dateModified\":\"2026-07-06T00:47:49+00:00\",\"description\":\"Le courant continu 800 volts brise le mur \u00e9lectrique dans les centres de calcul de l'IA : moins de cuivre, plus de puissance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg\",\"contentUrl\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg\",\"width\":1792,\"height\":1024,\"caption\":\"Serverracks mit 800-Volt-Anmutung f\u00fcr KI-Rechenzentren\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/2026\\\/06\\\/17\\\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/accueil\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/\",\"name\":\"cloudmagazin\",\"description\":\"Inspiration f\u00fcr Businessentscheider\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#organization\",\"name\":\"cloudmagazin\",\"url\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/cloudmagazin-logo-klein_menu.jpg\",\"contentUrl\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/cloudmagazin-logo-klein_menu.jpg\",\"width\":150,\"height\":150,\"caption\":\"cloudmagazin\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/cloudmagazincom\\\/\",\"https:\\\/\\\/x.com\\\/cloudmagazin\",\"https:\\\/\\\/www.linkedin.com\\\/showcase\\\/cloudmagazin\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/#\\\/schema\\\/person\\\/ce38baaa19a580268aedce096597eb3c\",\"name\":\"Alec Chizhik\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/alec-chizhik.jpg\",\"url\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/alec-chizhik.jpg\",\"contentUrl\":\"https:\\\/\\\/www.cloudmagazin.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/alec-chizhik.jpg\",\"caption\":\"Alec Chizhik\"},\"description\":\"Alec est le directeur num\u00e9rique chez Evernine et \u00e9crit sur les architectures cloud, la cybers\u00e9curit\u00e9 et les pratiques op\u00e9rationnelles num\u00e9riques.\",\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/alecchizhik\\\/\"],\"url\":\"https:\\\/\\\/www.cloudmagazin.com\\\/fr\\\/author\\\/alec\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud","description":"Le courant continu 800 volts brise le mur \u00e9lectrique dans les centres de calcul de l'IA : moins de cuivre, plus de puissance.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/","og_locale":"fr_FR","og_type":"article","og_title":"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud","og_description":"Le courant continu 800 volts brise le mur \u00e9lectrique dans les centres de calcul de l'IA : moins de cuivre, plus de puissance.","og_url":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/","og_site_name":"cloudmagazin","article_publisher":"https:\/\/www.facebook.com\/cloudmagazincom\/","article_published_time":"2026-06-17T13:42:15+00:00","article_modified_time":"2026-07-06T00:47:49+00:00","og_image":[{"width":1792,"height":1024,"url":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/07\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg","type":"image\/jpeg"}],"author":"Alec Chizhik","twitter_card":"summary_large_image","twitter_creator":"@cloudmagazin","twitter_site":"@cloudmagazin","twitter_misc":{"\u00c9crit par":"Alec Chizhik","Dur\u00e9e de lecture estim\u00e9e":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"NewsArticle","@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/#article","isPartOf":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/"},"author":{"name":"Alec Chizhik","@id":"https:\/\/www.cloudmagazin.com\/fr\/#\/schema\/person\/ce38baaa19a580268aedce096597eb3c"},"headline":"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud","datePublished":"2026-06-17T13:42:15+00:00","dateModified":"2026-07-06T00:47:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/"},"wordCount":2009,"publisher":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/#organization"},"image":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/07\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg","articleSection":["Centres de donn\u00e9es","Centres de donn\u00e9es"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/","url":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/","name":"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud","isPartOf":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/#primaryimage"},"image":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/07\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg","datePublished":"2026-06-17T13:42:15+00:00","dateModified":"2026-07-06T00:47:49+00:00","description":"Le courant continu 800 volts brise le mur \u00e9lectrique dans les centres de calcul de l'IA : moins de cuivre, plus de puissance.","breadcrumb":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/#primaryimage","url":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/07\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg","contentUrl":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/07\/800-volt-hvdc-rechenzentrum-cloud-kapazitaet-cover-hero.jpg","width":1792,"height":1024,"caption":"Serverracks mit 800-Volt-Anmutung f\u00fcr KI-Rechenzentren"},{"@type":"BreadcrumbList","@id":"https:\/\/www.cloudmagazin.com\/fr\/2026\/06\/17\/800-volt-gleichstrom-im-rechenzentrum-le-virage-de-nvidia-pour-le-cloud\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.cloudmagazin.com\/fr\/accueil\/"},{"@type":"ListItem","position":2,"name":"800-Volt-Gleichstrom im Rechenzentrum: le virage de NVIDIA pour le cloud"}]},{"@type":"WebSite","@id":"https:\/\/www.cloudmagazin.com\/fr\/#website","url":"https:\/\/www.cloudmagazin.com\/fr\/","name":"cloudmagazin","description":"Inspiration f\u00fcr Businessentscheider","publisher":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cloudmagazin.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.cloudmagazin.com\/fr\/#organization","name":"cloudmagazin","url":"https:\/\/www.cloudmagazin.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.cloudmagazin.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2020\/04\/cloudmagazin-logo-klein_menu.jpg","contentUrl":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2020\/04\/cloudmagazin-logo-klein_menu.jpg","width":150,"height":150,"caption":"cloudmagazin"},"image":{"@id":"https:\/\/www.cloudmagazin.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cloudmagazincom\/","https:\/\/x.com\/cloudmagazin","https:\/\/www.linkedin.com\/showcase\/cloudmagazin\/"]},{"@type":"Person","@id":"https:\/\/www.cloudmagazin.com\/fr\/#\/schema\/person\/ce38baaa19a580268aedce096597eb3c","name":"Alec Chizhik","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/03\/alec-chizhik.jpg","url":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/03\/alec-chizhik.jpg","contentUrl":"https:\/\/www.cloudmagazin.com\/wp-content\/uploads\/2026\/03\/alec-chizhik.jpg","caption":"Alec Chizhik"},"description":"Alec est le directeur num\u00e9rique chez Evernine et \u00e9crit sur les architectures cloud, la cybers\u00e9curit\u00e9 et les pratiques op\u00e9rationnelles num\u00e9riques.","sameAs":["https:\/\/www.linkedin.com\/in\/alecchizhik\/"],"url":"https:\/\/www.cloudmagazin.com\/fr\/author\/alec\/"}]}},"_links":{"self":[{"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/posts\/47034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/users\/31"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/comments?post=47034"}],"version-history":[{"count":2,"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/posts\/47034\/revisions"}],"predecessor-version":[{"id":48278,"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/posts\/47034\/revisions\/48278"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/media\/48275"}],"wp:attachment":[{"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/media?parent=47034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/categories?post=47034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/tags?post=47034"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/www.cloudmagazin.com\/fr\/wp-json\/wp\/v2\/industry?post=47034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}